Results & Evidence ​

This page is the canonical record of what has been measured on the Astronaut Health Intelligence Platform (AHI). Every number comes from a generated file, a test run or an observation stated as such. How these results fit into a validation plan: Validation strategy.

What these numbers mean

All engine results are measured on simulated data, against the same simulator that generated the data. They show internal consistency of the prototype rules, not real world sensitivity, specificity or clinical performance. Nothing here is validated on real crews.

Engine evaluation ​

Source: frontend/web/src/engine/evaluation.json, generated by npm run evaluate (scripts/evaluate.ts) on 2026-11-14 with engine ahi-engine 2.0.0. The same run regenerates docs/model-card.md.

Nominal false alerts ​

5 seeds (20261114 to 20261118) x 72 sim hours x 4 crew = 60 crew days, analytics every 15 sim minutes. In the nominal scenario nothing is wrong, so every alert counts as a false alert.

MeasureValue
Crew alerts at HIGH or above per crew day0
Crew alerts at MODERATE or above per crew day0
Cabin alerts0
Highest attention level reachedMODERATE (briefly, without an alert)
Share of time at LOW / MODERATE / HIGH / CRITICAL99.97% / 0.03% / 0% / 0%

Scenario detection ​

Minutes from the scenario start (08:00 UTC sim time), on the evaluation grid (1 min for acute cardio and sensor failure, 5 min for CO2, 15 min for fatigue and performance decline). Level is the target astronaut's attention level (cabin scenario: worst of the cabin and crew levels).

ScenarioTargetFirst alert (rule)HIGHCRITICALPeak (score)Simulated run
ACUTE_CARDIOAST-01 (ORION)7 min (R-HR-01)7 min7 minCRITICAL (100)3 h
SENSOR_FAILUREAST-03 (VEGA)14 min (R-DQ-02)not reachednot reachedMODERATE (20)3 h
ENVIRONMENTAL_CO2cabin90 min (R-ENV-CO2-01)140 min (2.3 h)not reachedHIGH (77)12 h
PROGRESSIVE_FATIGUEAST-02 (LYRA)1905 min (31.8 h, R-FAT-01)1980 min (33.0 h)not reachedHIGH (79)96 h
PERFORMANCE_DECLINEAST-04 (ATLAS)1650 min (27.5 h, R-EX-01)4530 min (75.5 h)not reachedHIGH (45)120 h

Reading the results.

  • The acute event is caught within minutes and is the only scenario that reaches CRITICAL, as designed.
  • Slow scenarios are capped at HIGH by design: they call for review, not an emergency response.
  • The sensor failure is a data quality case: it reaches MODERATE ("signal lost, status unknown") and never looks normal.
  • The fatigue pattern needs more than a day of evidence before the combined rule fires, which is the intended trade-off against false alerts.

An issue the evaluation found ​

The evaluation found and fixed a real problem: nominal false alerts on blood pressure during exercise warm-up. The fix is the upward only acute rule in the exercise context (Anomaly detection).

Reproduce ​

bash
cd frontend/web
npm run evaluate

Tests ​

MeasureValue (2026-11-16)
vitest tests (web)450 in 49 files, all passing
pytest tests (backend)91 in 7 files, external HTTP mocked
Anatomy atlas validation (npm run anatomy:validate)passes on the published files: 250 structures in 9 GLB files, 880,356 triangles, 4.64 MB
Typecheck (npx tsc -b)clean
Production build (npx vite build)ok

What each file covers: Testing strategy.

Measured performance ​

Informal observations by the team on one development laptop (AMD Ryzen 5 3500U, integrated Radeon Vega 8 graphics), not a controlled benchmark. Nothing here was repeated on other machines.

3D atlas viewer (headless Chrome, frame rate capped at 60 by vsync). The full table, with draw calls and triangles per frame, is in 3D anatomy.

MeasureValue
Frame rate, default systems58 to 60 fps
Frame rate, all nine systems56 to 59 fps
Frame rate, Ground view at 1440x90055 to 57 fps
Frame rate, Ground view with a body system detail open39 to 42 fps (the detail panel is the limit: the previous procedural viewer measured 38 in the same state)
Hover pick0.4 to 2.8 ms per raycast
Atlas on screen after navigation, warm browser cache2.4 to 3.6 s
Atlas size4.64 MB in 9 files (880,356 triangles); the default view downloads 8 files, about 3.0 MB

Engine and app. The first three rows were measured before the atlas viewer replaced the procedural body and were not measured again.

MeasureValue
Frame rate at 60x simulation speed (procedural body)58 to 60 fps
Frame rate at 3600x (procedural body)about 45 fps
3D body height at 1280x720 with an active critical alert (procedural body)247 px before, 359 px after the banner overlay change
Startup pre-generation (from the engine docs)about 1.2 s warm, 2 to 3 s cold
What-if comparisonunder 5 ms per call

Evidence that is not available ​

EvidenceStatus
Accuracy on real astronaut dataNot available: no public continuous data, no labeled outcomes
Sensitivity and specificity against a clinical referenceNot available
Usability study with crew or flight surgeonsNot done
Performance on other machines, browsers or screensNot measured
Anatomical review of the 3D atlas by a specialistNot done; the model is used as published by Z-Anatomy, simplified by the asset pipeline
Formal accessibility auditNot done
Visual regression on Windows (only Linux baselines are committed)Not done

Next steps ​

Astronaut Health Intelligence Platform. Decision support only: not a diagnosis and not a medical device. Device data is simulated.