Skip to content
StatusImplementedVerified on

Responsible Use ​

The Astronaut Health Intelligence Platform (AHI) deals with health information, so its limits are part of the product, not a footnote. This page states what AHI is, what it is not, and the rules every screen, record and contribution follows.

Medical disclaimer

AHI is a monitoring, trend analysis and decision support prototype. It is not a medical device, not certified, not validated on real crews and not meant for real patients. It does not diagnose, does not recommend medication or treatment, and does not replace the flight surgeon or Mission Control. Fixed thresholds are demo configuration, not official NASA limits. Simulated data is not clinical evidence.

Decision support boundaries ​

AHI doesAHI does not
Compare each person with their own baselineDiagnose a condition or name a disease
Describe deviations, trends and uncertaintyPrescribe medication or treatment
Suggest non-prescriptive next steps from a versioned catalog ("Review sleep schedule and light exposure", "Request flight surgeon review now")Replace the flight surgeon or Mission Control
Say who can act (crew on board or flight surgeon on Earth)Make autonomous clinical decisions
Flag missing or questionable dataClaim a live connection to ISS devices
Show hypothetical what-if projectionsClaim clinical efficacy of any action

The wording follows the same line: the app says "Act soon" or "Needs flight surgeon", never a disease name. Simulated flight surgeon replies are templates that never prescribe medication and state that they are simulated.

Human in the loop ​

  • Every HIGH or CRITICAL recommendation, and every item addressed to the flight surgeon, requires human review (requiresHumanReview).
  • Alerts stay open until a person acknowledges them or the rule has been clear for a while; unacknowledged CRITICAL and HIGH alerts escalate (Alerts and escalation).
  • Every human action (acknowledge, mark done, check-in, message to Earth) and notable system event is written to the audit trail with time and actor.
  • Self report never escalates on its own: a check-in alone reaches MODERATE at most.

Correlation is not causation ​

When cabin CO2 rises and the crew's breathing rate and reaction time shift at the same time, AHI reports a co-occurrence (rule R-ENV-CO2-02 states "This is co-occurrence, not proof of cause"). Combined rules show signals that moved together; they do not prove why.

Thresholds and plans are demo configuration ​

Status is driven by personal baseline bands. The few fixed thresholds, the mission plan (180 days, 100 mGy radiation budget, 60 min exercise per day, 8 h sleep), escalation timings, Earth review times and every intervention effect size live in src/engine/config.ts and are labeled "demo configuration, not an official limit". The values are listed once, in Thresholds and limitations.

Simulated data is labeled everywhere ​

  • The top bar always shows a SIMULATED badge; charts, messages and reports repeat the label.
  • Public data is never presented as live telemetry, and other people's data is never merged into the crew.
  • Missing data is never treated as normal: it becomes NO_DATA, shown in grey with the words "Signal lost".

Labels and their rules: Data origins and provenance. Privacy and handling rules: Governance and privacy.

Use of AI ​

There is no language model, no trained machine learning model, no retrieval and no agent at runtime. The project was developed with AI assistance (Claude Code), which is a development tool, not a platform feature. Details and the planned, guarded explanation layer: AI and analytics approach.

If you build on it ​

  • Keep every fixed number in config.ts with the demo label until a qualified person reviews it with a citable source.
  • Keep the data origin on every record.
  • Do not add diagnostic wording, medication or treatment advice to any text.
  • Validate on real, appropriately consented data before any operational claim (Validation strategy).

Next steps ​

Astronaut Health Intelligence Platform. Decision support only: not a diagnosis and not a medical device. Device data is simulated.