A health monitor is used with busy eyes and busy hands: during exercise, during a procedure, from across a module. The Astronaut Health Intelligence Platform (AHI) therefore says important things in more than one way: color plus icon plus words, sound for alerts that need action, speech on request, and a full keyboard path, including the 3D body.

All settings live in Tools > Accessibility and sound and are remembered per device.

Alert sounds ​

RuleBehavior
What ringsOpen (not acknowledged, not resolved) critical alerts; warnings too if "Also for warnings" is on
DefaultSound for critical alerts on, warnings off
SoundOne short tone pattern (earcon) per severity, generated with the Web Audio API: no audio files
RepeatEvery 30 s while a critical alert stays open; every 2 min for a warning
EscalationA critical alert still unacknowledged after 2 min (or escalated by the engine) switches to a more urgent sound that repeats every 15 s
One sound at a timeThe most urgent open alert decides the sound; five open alerts never make five sounds
History is silentAlerts created before the page loaded or before the scenario restarted never ring
Blocked audioIf the browser blocks sound until a click, an Enable sound prompt appears

The rules follow the spirit of the IEC 60601-1-8 alarm guidance (avoid alarm fatigue, escalate what is ignored). The intervals are demo configuration, not an official limit. Repeats count real time, not simulation time, so a fast simulation does not make the app beep faster.

Audio description ​

Spoken explanations with the browser's built in speech synthesis. Off by default. Nothing is sent anywhere.

KeyAction
DDescribe the screen (press again to stop)
Shift + DTurn audio description on or off
EscStop speaking

When on, it reads new critical and high alerts, status changes and what you select. Voice speed goes from 0.6x to 1.6x. Every spoken health summary says the data is simulated, and missing data is spoken as "no data", never as normal. Screen reader users may not need it: the same events are announced through aria-live regions.

One voice at a time across a language change. Changing the language cancels every voice: the speech synthesis and every app queue (audio description, describe the screen, the assistant read aloud), so nothing keeps talking in the old language. The on screen description closes too, since its text is in the old language. With audio description on, AHI then says one short sentence in the new language (in English: "Speaking English now."), after a pause of 150 ms because some speech engines drop an utterance queued right after a cancel.

Keyboard and the 3D body ​

The 3D viewer has a keyboard path, the body navigator (3D anatomy):

KeyAction
TabReach the body navigator
Up / DownPrevious or next monitored region
Left / RightPrevious or next structure in the region
Home / EndFirst or last
EnterSelect
EscClear the selection

Each move is announced, for example "Heart region. Status: Nominal." A region with no readings is announced as "no data".

Global shortcuts (1 to 4, V, P, A, Space, ? and others) are listed in the app with ? and in Design system.

  • Two skip links are the first focusable elements: Skip to main content and Skip to what needs attention (the attention panel in Ground view, the actions card in Crew view).
  • aria-live regions announce alerts, status changes and the body navigator; the assistant conversation is a log region.
  • Status never relies on color only; prefers-reduced-motion slows and dims the body scan and disables animations.
  • Visual first panels keep their sentences behind a Details toggle. While closed, the text is only visually hidden (sr-only), so screen readers and audio description still get it. Gauges carry an accessible label with the value, the personal normal and the status in words.
  • An open CRITICAL alert also puts a red dot on the browser tab icon, a cue that works when the tab is hidden.
  • The mission backdrop is decorative (aria-hidden); its parallax and animations stop under reduced motion.

Languages ​

English is the default and the reference language for the international judging; it is identical with or without the language layer. Plain language comes first and the technical term second (for example "Breathing rate" before "respiratory rate").

Four other languages are optional: Português (Brasil), Español, 日本語 and Deutsch. Pick one in Tools > Language.

RuleBehavior
Status of the translationsMachine assisted, pending real native review. A native style review of the wording was done and the glossary of fixed terms is in docs/i18n-glossary.md, but no native speaker has reviewed them yet. Each non English entry in the picker says so in its tooltip; only English is reviewed
DefaultEnglish. The browser language is never applied automatically; the choice is remembered on the device
LoadingEnglish ships in the main bundle; the other languages are separate chunks downloaded only when picked. Japanese loads a Japanese font on demand
Way backOutside English the menu item reads "Language" in both languages, so anyone can switch back
What stays untranslatedSIMULATED, REAL_PUBLIC, metric codes, rule ids and units; messages and reports sent to the ground stay in English
SpeechAudio description uses a voice of the selected language when the system has one

A unit test checks that every language has exactly the English keys, no empty strings, the same placeholders, no dash characters and the protected tokens untranslated. Experimental until the native review is done.

Engine text ​

The health engine writes its sentences in English (risk headlines, factors, recommendations, alerts, region summaries). Next to each sentence it attaches a structured message: a stable id plus parameters (src/engine/msg.ts). The interface renders engine text through src/i18n/engineText.ts, never the raw English field:

  • In English the engine's own sentence is returned unchanged.
  • In another language the message is rendered from its eng.* keys; metric and region names, units and durations come from the catalog.
  • If a message or one of its keys is missing, the English sentence is shown, never a half translated one.
  • A caller that only has the English text still gets a translation: the engine remembers each sentence it produced together with its message.

engineText.test.ts checks that English stays identical and that translated messages render. Covered today: risk headlines, factors, recommendations, alerts, region summaries, exam notes, forecast notes, device pause and signal notes and the autonomy guidance; the mission profile texts and hazard names render through the same file. Plain text handover and packets to the ground stay English by design. A sentence that carries no structured message is shown in English, and the pseudo locale below makes such text visible.

Finding untranslated text ​

Two developer tools, not part of the product:

ToolWhat it does
Pseudo locale qpsDev builds only. Open the app with ?lang=qps (or set ahi.pseudo.v1 in local storage); ?lang=en turns it off. Every translated string is wrapped in ⟦ ⟧, so plain English without brackets on screen bypassed the translation layer. Dates, numbers and the picker stay English. Never in the language picker, never in production builds
node scripts/i18n-sweep.mjsRun inside frontend/web (--json for machine output). Lists JSX text and literal title, aria-label, placeholder, label and alt values in src/features that bypass t(). A heuristic: review each hit before translating

Limitations ​

  • No formal WCAG audit and no structured screen reader test has been done yet.
  • Speech synthesis and recognition quality depend on the browser and the operating system voices.
  • The earcons are designed for distinctness, not validated against a standard alarm sound set.
  • Engine sentences without a structured message, and the plain text handover and ground packets, stay in English when another language is selected (Engine text).

Status ​

Implemented Alarm scheduling (alarmSchedule.test.ts), spoken text (describe.test.ts), the speech stop on a language change (languageSpeech.test.ts), engine text rendering (engineText.test.ts) and the tab icon rule (useStatusFavicon.test.ts) are unit tested.

Next steps ​

Astronaut Health Intelligence Platform. Decision support only: not a diagnosis and not a medical device. Device data is simulated.